June 24: "Baseline" Stability in TBF for Comparison to RASHOMS
Configuration:
- ACS: Fully Assembled
- Mounting: In TBF/Diamond with New Linear Bearing B-Latch
- Cooling: Chillers
- Optical Source: HRC Coronagraph Spot with Backlight; WFC RAS/Cal
- Starting Temp: Ambient at Start of Day
- Add'l Sensors: LVDTs to Monitor Motion of Bench Relative to Enclosure
Test Sequence for Baseline:
- T=0 (1300GMT) ACS On/WFC TECs On
- T=4 Hr HRC TEC On
- T=7 Hr Chillers On
- T=11 Hr Chillers Off
- T=14 Hr Test End
Results:
- "Warmup" and Chillers On Effects Present at ~0.5 pixels &Chillers
Off Effect Present at ~1 pixel
- TBF Cube Motion of ~8 as and AC1 Motion of ~3 as Observed During
Chillers On (Optical Cube Data was Taken Only During the Chillers On
Segment from 1540-1800)
- LVDTs Show Small TBF Expansion Correlated w/Chillers On & Off
- Cube & LVDT DataIndicates Chiller Effect is (Partially?) Caused by
TBF Loading the Enclosure